Stainless steel
- Wipe with a soft cloth and a mild, compatible cleaner.
- Wipe along the grain of brushed finishes.
- Rinse off residue and dry to avoid water marks.
- Do not use steel wool or wire brushes.
Practical guidance for maintaining surgical instruments and hospital furniture, helping preserve their appearance, functionality and service life.
Safety noticeThese pages provide general care and maintenance information. Always follow the product-specific Instructions for Use, the instructions supplied by the relevant equipment manufacturer, applicable standards and your healthcare facility's infection-prevention procedures.
Careful handling, prompt cleaning and regular inspection help reusable stainless steel instruments keep their finish and function.
Hospitime instruments are supplied non-sterile. Clean and sterilise them before first use, following the product IFU.Cleaning must come before disinfection or sterilisation. Organic and inorganic material left on an instrument interferes with these processes.
Use soft brushes and lint-free cloths. Clean below the water surface to limit splashing, and brush hinges, serrations and lumens.
Use where the IFU allows. Open hinged instruments fully and do not overload the basket.
Use the validated cycle your facility has approved. Load instruments so all surfaces can be reached.
Inspect every instrument after cleaning, preferably under magnification and good light. Remove any damaged or worn instrument from service.
Lubricate hinges, box locks and moving parts only when the product IFU calls for it. Use an instrument lubricant suited to the sterilisation method, as directed by the lubricant manufacturer. Do not use general-purpose oils.
Removes visible soil and organic material. It is required before any disinfection or sterilisation.
Kills many or all pathogenic microorganisms, but not necessarily bacterial spores.
Destroys all forms of microbial life, including spores, by a validated process.
Beds, trolleys, stools and cabinets combine several materials. Clean each one with a product its manufacturer approves, and check moving parts regularly.
Use cleaning and disinfecting products approved by your facility and compatible with the surface. Follow the product manufacturer's instructions for dilution and contact time.
Tick each item as you check it. Ticks are not saved.
An example of how a schedule could be organised. Set your actual schedule by your facility's infection-prevention policy and the product IFU.
Example only · not mandatory| Item | Example timing | Example activity |
|---|---|---|
| Surgical instruments | ||
| Reusable instruments | After every use | Point-of-use care, cleaning, rinsing, drying and inspection |
| Reusable instruments | Before every use | Sterilisation by a validated process, as the IFU specifies |
| Hinged instruments | As the IFU specifies | Lubrication |
| Hospital furniture | ||
| High-touch surfaces (rails, controls) | Daily and between patients | Cleaning and disinfection with approved products |
| Whole bed, trolley or stool | When a patient is discharged | Full cleaning of all surfaces |
| Castors and brakes | Weekly | Debris removal and function check |
| Mechanisms and electrical parts | Periodically, per manufacturer | Inspection by trained or qualified personnel |
Swipe the table sideways to see all columns.
Print a checklist or save it as a PDF. These are general checklists, not Instructions for Use.
Handling, cleaning, drying, inspection and storage checks.
Surface cleaning, electrical safety, castors, brakes and mechanisms.
Send us the product name. Our team will share the care information available for that item.